Create and Administer vCenter Server Alarms
– Create and Administer vCenter Server Alarms
For this objective I used the following resources
- vSphere Resource Management guide
- VMware vSphere Examples and Scenarios guide
Knowledge
List vCenter default utilization alarms
Alarm | Description |
Virtual machine memory usage | Default alarm to monitor virtual machine memory usage |
Virtual machine cpu usage | Default alarm to monitor virtual machine cpu usage |
Datastore usage on disk | Default alarm to monitor datastore disk usage |
Host memory usage | Default alarm to monitor host memory usage |
Host cpu usage | Default alarm to monitor host cpu usage |
List courtesy of the Alarms tab at the root of vCenter
List vCenter default connectivity alarms
Alarm | Description |
Cannot connect to storage | Default alarm to monitor host connectivity to storage device |
Host connection and power state | Default alarm to monitor host connection and power state |
Host connection failure | Default alarm to monitor host connection failure |
Network connectivity lost | Default alarm to monitor network connectivity on a virtual switch |
Network uplink redundancy degraded | Default alarm to monitor network uplink redundancy degradation on a virtual switch |
Network uplink redundancy lost | Default alarm to monitor loss of network uplink redundancy on a virtual switch |
List courtesy of the Alarms tab at the root of vCenter
List possible actions for utilization and connectivity alarms
Host related actions
- Send a notification email
- Send a notification trap
- Run a command
- Enter maintenance mode
- Exit maintenance mode
- Enter standby
- Exit standby
- Reboot host
- Shutdown host
VM related actions
- Send a notification email
- Send a notification trap
- Run a command
- Power on VM
- Power off VM
- Suspend VM
- Reset VM
- Migrate VM
- Reboot guest on VM
- Shutdown guest on VM
Create a vCenter utilization alarm
For this excercise we are going to create a host alarm based on network utilization
- From the root object in vCenter select the Alarms tab
- Select the Definitions tab next to View
- In the right hand, right click in open a space and select New Alarm
- In the General tab give the alarm a Name, Description, and select Hosts from the Alarm Typedrop down.
- Select the Triggers tab
- Right click in the open space and select Add Trigger
- Click the trigger type to display the list of available triggers
- From the list select Host Network Usage (kbps)
- For the Warning and Alert values select what is appropriate for your environment
- Click the Actions tab
- Right click in the open space and select Add Action
- Select Send a notification email
- Under the Configuration column input your email address
- Leave the default setting to email when going from a warning state to an alert state
- Click OK
Create a vCenter connectivity alarm
For this exercise we are going to create a host alarm based on lost storage path redundancy
- From the root object in vCenter select the Alarms tab
- Select the Definitions tab next to View
- In the right hand, right click in open a space and select New Alarm
- In the General tab give the alarm a Name, Description, and select Hosts from the Alarm Typedrop down.
- Select Monitor for specific events occuring on this object, for example, VM powered on
- Select the Triggers tab
- Right click in the open space and select Add Trigger
- Click the trigger type to display the list of available triggers
- From the list select Lost Storage Path Redundancy
- Click the Actions tab
- Right click in the open space and select Add Action
- Select Send a notification email
- Under the Configuration column input your email address
- Leave the default setting to email when going from a warning state to an alert state
- Click OK
Configure alarm triggers
See sections above Create a vCenter Connectivity Alarm and Create a vCenter Utilization Alarm. Also review pages 33 thru 39 of the vSphere Monitoring and Performance documentation.
Configure alarm actions
See sections above Create a vCenter Connectivity Alarm and Create a vCenter Utilization Alarm. Also review pages 33 thru 39 of the vSphere Monitoring and Performance documentation.
For a give alarm, identify the affected resource in vSphere implementation
If using any of the default vCenter alarms the alarm name as well as the alarm description should identify which resource is being affected.
Tools
- vCenter Server and Host Management guide
- vSphere Resource Management guide
- vSphere Monitoring and Performance guide
- VMware vSphere Examples and Scenarios guide
No comments: